Mildew resistant tester

Mildew resistant tester

Model No.︰JL-380

Brand Name︰-

Country of Origin︰China

Unit Price︰CNY ¥ 380 / pc

Minimum Order︰1 pc

Inquire Now

Product Description

A, use characteristics

Use: the instrument suitable for leather, wood, cardboard, plastic, rubber,walls, sofa, furniture, fiber and so on material, water content in 7%-35%objects, such as leather products: shoes, handbags, furniture, textiles, rapid determination of percent moisture content of chemical raw materials and so on goods.

Characteristics: this instrument set measuring device, display, power supply, circuit board in one, compared with similar products of the instrument and domestic, is has the advantages of small volume, light weight, fast test speed, simple operation, beautiful appearance, exquisite workmanship, easy to carry the advantages.

Two, technical indicators

Display: light emitting diode display, a total of 10

Measuring range: the range of I 7-15% range II 16-35%

The measurement accuracy: +1 display value (moisture)

Working voltage: 15V DC

Conditions of use: the test temperature of 0~40 ℃ ambient relative humidity<85%

Size: 185*50*27mm weight: About 180g

Three, the use of methods:

A dry battery: connect the seven dry cell batteries into the battery boxsections.

Check the instrument: use the left needle short (on hand or metal) press the range switch I, then the following a luminous tube should be light. Open circuit (no conductive objects around the wire connection) press measuring switch, then the luminous tube should not light, if can meet the above requirements that the normal instrument, can be tested.

Measurement of objects (such as: measurement of leather) to test fourneedle into the material depth is about 6mm, press the range switch, read-out display LEDs corresponding readings. If you press is the range of Iswitch, then read the left line readings. If the press is range I I switch, thenread on the right side of the line.

The following several cases when reading attention when measuring.

Press the range of I switch, if the display no light, the reading below 7%, if the display only the following a light emitting diodes, that reading is higher than or equal to 15%, should be replaced by I I switch, and then reading.

Press the range I I switch, if the display no light, the reading below 16%,should be replaced by the I switch to reading, if the display only thefollowing a light emitting diodes, that reading is higher than or equal to 35%.

Press the range I switch or range of I I switch, if the display of two adjacentlight emitting tube is light, is reading desirable two the average of the readings, can also according to different brightness, reading a sliding scale.

Replace the battery: if the above check is not up to the requirements, ordisplay lighting dim, you should replace the new battery.

Four, repair and maintenance

1, the instrument is in the high impedance instrument, each place should have good insulation, use the save to pay attention to moisture and dust,keep clean and dry, so as not to affect the accuracy of measurement.

2, light emitting diodes working current is about 5mA, the dry battery only intermittent discharge, so usually don't long time press the range switch,only when the inspection or measurement readings only short time press the can, can save electricity.

2, instrument storage place should be clean, the environment temperature is 0 ~ 40 ℃, relative humidity is less than 85%, if not used for a long time, toremove the battery from the box.

 

 